Sign In | Join Free | My burrillandco.com
Home > Elevator Load Weighing Device >

SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device

    Buy cheap SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device from wholesalers
     
    Buy cheap SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device from wholesalers
    • Buy cheap SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device from wholesalers
    • Buy cheap SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device from wholesalers

    SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device

    Ask Lasest Price
    Brand Name : SUMT, ANT
    Model Number : OMS-560-RHP-F-3T
    Price : USD80-150/PC
    Payment Terms : T/T, Western Union, MoneyGram,Paypal
    Supply Ability : 5000-1000pcs/month
    Delivery Time : 3-20 working days depending on the quantity
    • Product Details
    • Company Profile

    SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device

    SUMMIT Split type elevator overload control system 3000kg RHP-F-OMS-560 installed at elevator the rope hitch ;oint overload measurement control device
    Installation loacation: installed at wire rope hitch point :OMS-560-RHP-F-3T(rated load: 3000kg)

    Description:
    The elevator over load control device OMS-560-RHP-F is one kind of split type load weighing solution ,and it consists of 1 or 2 pressure load sensor RHP-F and a controller OMS-560, and the pressure load cell is typically plated under the wire rope hitch plate. This method have no impact on the crossing height requirements and are there-fore especially suitable for new installation and modernization projects.
    Features:

    1. Cost efficient and precise method
    2. Very easy to install
    3. Static load at fixing point(under the plate of wire rope attachment)
    4. Suitable for the new installations and modernization project
    5. Menu-guided operation
    6. 5 relays output overload,full,half empty,optical, audio output
    7. DIN Rail or on flat surface mounting with screws
    8. IP-65 rated plastic box.
    9. Integrated software to correct weight increases due to compensating chain.
    10. Display load as well as percentage
    11. Protecting important data from being disturbed by password
    12. Automatic correction of zero drift, makes the equipment in optimum stage
    13. Self-learning function, regulating high floor additional weight error
    14. Control equipment swap entirely,self-diagnosis and alarming
    15. Self-learning operating conducted by any fixed load

    Control Unit:OMS-560
    Operation VoltageAC/DC16-48VSensor operation voltageDC5V
    Nominal power4WSignal Hold VoltageAC/DC12-45V
    Input Channel (Load Cell )2Measuring precision0.1%
    Relay Number

    5(overload,full,half empty,optical, audio output)

    Operation temperature-45degree-+85degree
    Contact Load8A250VAC,5A 250VAC,5A 30VDCSize90x84x58mm
    Display Type4 digits 0.56 inch LEDWeight265g
    Display modeWeight/percentageShell materialABS


    Model:RHP-F
    Rated Load3000kg/PCOutput Resistance700M+/-2 ohm
    Rated Output2.0+-0.02%mv/vSafe Overload150% F.S.
    Total error+/-0.5% F.SUltimate Overload200% F.S.
    Repeatability+/-0.5% F.S.Construction materialStainless Alloy steel
    Creep 30min+/-0.05% F.S/30minProtection ClassIP68
    Zero Balance+/-1% F.S.Insulation impedance≥5000Ω
    T C SPAN+/-0.02% F.S./10 degree CelsiusCable length8m(black)
    Operation temperature range-30 to 70 degree CelsiusConnection type4 bank wire
    Input Resistance760+/-10 ohm
    Excitation
    DC 5-12V


    Wiring Diagram:

    4 blank wires:

    Installation location&Size:



    Instruction:
    The purpose of the SUMMIT Load Weighing system is to measure the load in the elevator and pro-vide usable information about the load to the elevator controller. This information is used forpre-torquing and for dispatching decisions, e.g. light load anti-nuisance, heavy load and over-load.
    The system usually consists of a sensor or group of sensors mounted on the elevator’s some position such as clamping on wire rope, or under cabin, under the wire rope plate installation and a control unit. The sensor(s) provide a signal to the control unit directly related to the amount of load in the cab. The load weighing control accepts this signal and provides usable data to the elevator controller in the form of an analog signal and discrete relay contacts.

    Using SUMMIT solutions loads can be weighed in every imaginable situation.We offer you flexible, modular solutions for both requirements, and wide experience with modernization projects. we attention to detail in the design of their modular system allows great freedom to configure load weighing systems to suit all types of cabin.

    Quality SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo youte electric Co.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)